Control panel operation
Red stop, green start, touchscreen, and emergency stop are on the cantilever-mounted panel.
Fig. 16 — Control panelTrial run & acceptance
Complete no-load tests in manual mode before loading material.
- Pre-run: power + air connected; E-stop functional; travel path clear
- Manual mode: test press plate, feed, drag chain separately
- With material: align feed rails; run automatic mode; check processing result
- Acceptance: level OK; smooth motion; no air leaks; no electrical alarms
Fig. 17 — Trial operationMaintenance schedule
Follow the interval table to keep feed accuracy and pneumatic reliability.
- Daily: clean work surface and brush bar; check E-stop
- Weekly: inspect air fittings; clean drag chain
- Monthly: lubricate screw and guides; tighten loose bolts
- Quarterly: replenish lubricating oil; check sensor sensitivity